| Sign In | Join Free | My chinacomputerparts.com | 
 | 
Brand Name : wanbo
Model Number : WBP-T10M
Place of Origin : China
MOQ : 1Set
Price : Negotiation
Delivery Time : 7-15 working day
Payment Terms : L/C, T/T
Supply Ability : 1 ~ 5000 piece 30days
Product Model : WBP-K02Z-PLC
Product Name : Indoor PLC Zone Controller
Weight : 3.5Kg
Shell material : Galvanized plate
Communication mode : 1route CAN;2routeRS485/ 1routepowerbus
Consumption : ≤2W
Node capacity : RS485:50 pcs (including detector and guide split screen) Powerbus:42pcs (including detector and guide split screen)
| Product model | WBP-K02Z-PLC | 
| Specification and size | 320×260×90mm | 
| Net weight | 3.5Kg | 
| Housing material | Galvanized plate | 
| Node capacity | RS485:50 pcs (including detector and guide split screen) Powerbus:42pcs (including detector and guide split screen) | 
| Operating voltage | AC 110~240V | 
| Operating temperature | -30 ~ +75℃ | 
| Communication mode | 1route CAN 2routeRS485/ 1routepowerbus | 
| Communication distance | CAN:≤1000m RS485:≤300m powerbus≤130m | 
| Power consumption | ≤2W(Own power consumption, without detector) | 
Table 3.1 Technical parameters of the indoor zone controller

The indoor PLC zone controller is used to check the status of the connected detector and upload the relevant information to the indoor node controller.
The indoor PLC zone controller is used to connect the indoor node controller and the parking detector, LED display screen, etc., using RS485, CAN bus hybrid communication mechanism, to solve the problem of unreliable long-distance communication, network node number expansion problem, group management problem.
1) The equipment has short-circuit, overvoltage and overload protection functions to prevent electrical damage to related equipment due to wiring errors during construction;
2) The overall industrial design, through strict static electricity, lightning and surge, group pulse testing, effectively ensure the reliable use of equipment;
3) It can quickly and effectively detect various states of the equipment, detect the communication of the equipment with one key after installation, and quickly diagnose the bus connection.
4) Support remote upgrade.
Product Installation
   The indoor zone controller is usually installed on a column or wall, and is recommended to be installed at a height of 2 meters or more. The installation diagram is shown in Figure 4.1:
Parking Control K02ZPLC Indoor Zone Controller Using RS485 CAN Bus Hybrid Communication Mechanism
|   | 
| K02ZPLC Indoor Zone Controller Using RS485 CAN Bus Hybrid Communication Mechanism Images | 
 110-240V Parking Control K02Z Indoor Zone Controller RS485 CAN Bus Ultrasonic
                                                                                        
                                                        
                        
                        
                        
                                                            110-240V Parking Control K02Z Indoor Zone Controller RS485 CAN Bus Ultrasonic
                                                    
                        
                     K02Z Parking Control 350W Indoor Zone Controller Ultrasonic RS485 Guidance PGS
                                                                                        
                                                        
                        
                        
                        
                                                            K02Z Parking Control 350W Indoor Zone Controller Ultrasonic RS485 Guidance PGS
                                                    
                        
                     K04ZW CAN Indoor Wireless Zone Controller Ultrasonic PGS Parking Control
                                                                                        
                                                        
                        
                        
                        
                                                            K04ZW CAN Indoor Wireless Zone Controller Ultrasonic PGS Parking Control
                                                    
                        
                     K04ZW Parking Control Ethernet Indoor Wireless Zone Controller Ultrasonic PGS
                                                                                        
                                                        
                        
                        
                        
                                                            K04ZW Parking Control Ethernet Indoor Wireless Zone Controller Ultrasonic PGS
                                                    
                        
                     K03ZV PoE VPGS Indoor Video Zone Controller Camera LPR Recognize Parking Control
                                                                                        
                                                        
                        
                        
                        
                                                            K03ZV PoE VPGS Indoor Video Zone Controller Camera LPR Recognize Parking Control
                                                    
                        
                     K04M VPGS LPR Video Centralized Controller Guidance Software
                                                                                    
                        
                        
                        
                                                            K04M VPGS LPR Video Centralized Controller Guidance Software
                                                    
                        
                     K04MP Parking Control VPGS LPR Video Centralized Controller Guidance Software
                                                                                    
                        
                        
                        
                                                            K04MP Parking Control VPGS LPR Video Centralized Controller Guidance Software
                                                    
                        
                     K03ZWE IP66 Ethernet Outdoor Wired Zone Controller PGS RS485
                                                                                        
                                                        
                        
                        
                        
                                                            K03ZWE IP66 Ethernet Outdoor Wired Zone Controller PGS RS485
                                                    
                        
                     K03N Parking Control Outdoor Wired Node Controller RS485 PGS IP66 Guidance
                                                                                        
                                                        
                        
                        
                        
                                                            K03N Parking Control Outdoor Wired Node Controller RS485 PGS IP66 Guidance
                                                    
                        
                     K02GLW Parking Control LoRaWAN Gateway Outdoor Guidance WiFi Ethernet 868 433
                                                                                        
                                                        
                        
                        
                        
                                                            K02GLW Parking Control LoRaWAN Gateway Outdoor Guidance WiFi Ethernet 868 433